Groen Steam Jacketed Gas Kettle- 40 Gallon. Model: AH/1-40. Nat'l Bd: 77210. Gas-fired: natural. MAWP @ 300 °F: 30 psi. Input rate: 100,000 Btu/h. Open top with lift-top lid. Electrical requirements: 115 V, 1 amp, 60 Hz, single phase. Inlets: (1) 3/4 in. dia. FNPT (jacket), (1) 1/2 in. dia. MNPT (natural gas), (1) 2 in. dia. pilot access door. (1) 4 in. burner sight port. Outlets: (1) 1-1/2 in. dia. discharge, (1) 6 in. dia. exhaust port. Overall dimensions: 3 ft. 6 in. L x 3 ft. W x 3 ft. 9 in. H. (ACN97).
Groen Gas-Fired Jacketed Kettle- 5 Gallon. Model: TDH/20. NB & S/N: 131786. Stainless steel. MAWP: 50 psi @ 300 °F, MDMT: 50 °F @ 50 psi. The Groen Model TDH 20-quart is a self-contained, steam jacketed unit, operating from gas heated steam. Typical applications: browning meats, sauces, vegetables, seafood, soups, rice, pasta, stews, pie fillings, reheating cook-chill & prepared foods. Main burner operation/system includes: thermostat, pressure gauge, gas regulator valve, heating indicator lamp, on/off switch. Front mounted water level sight glass: 1-1/4 in dia. Natural gas, input rate: 0.92 hp (boiler) (31000 BTU/hr) with (8) burners. Steam outlet: 15-1/2 in. L x 2 in. W. Manifold gas pressure: 3.5 in. W C. Electric requirements: 115 V, 60 Hz, 1 amp, 1 phase. Jacket inlet/outlet: (2) 1 in. threaded female. Overall dimensions: 34 in. L x 26 in. W x 31 in. H.
Groen Gas-Fired Steam Jacketed Kettle- 5 Gallon. Model: TDH/20. NB & S/N: 21401. Type of gas: Natural. MAWP: 50 psi at 300 °F. MDMT: 50 °F at 50 psi. Recommend use of distilled water for jacket. Input rate: 0.92 boiler hp (31000 BTU/hr). (8) burners. Manifold gas pressure: 3.5 in. WC. Electrical requirements: 115 V, 60 Hz, 1 amp, single phase. The Groen Model TDH 20 quart has stainless steel construction, self-contained, steam jacketed unit operating from a gas heated steam. Typical applications: Browning meats, Sauces, Vegetables, Seafood, Soups, Rice, Pasta, Stews, Pie fillings, Reheating Cook-Chill & Prepared Foods. Tilt mechanism. Jacket inlet/outlet: (2) 1 in. threaded female. Steam vent: 15-1/2 in. L x 2 in. W. Overall dimensions: 34 in. L x 26 in. W x 31 in. H.
1996 Groen Gas-Fired Stainless Steel Jacketed Kettle-10 Gallon. NB & S/N: 42780. Model: TDH/40. Material of construction: 304 stainless steel. MAWP: 50 psi @ 300 �°F, MDMT: 32 �°F @ 50 psi. The Groen Model TDH 40-quart is a self-contained, steam jacketed unit operating from a gas heated steam. Typical applications: browning meats, sauces, vegetables, seafood, soups, rice, pasta, stews, pie fillings, reheating cook-chill & prepared foods. Main burner operation/system includes: thermostat, pressure gauge, gas regulator valve, heating indicator lamp, on/off switch. Front mounted water level sight glass: 1-1/4 in dia. Natural gas, input rate: 1.55 hp (boiler) (52000 BTU/hr) with (12) burners. Steam outlet: 17 in. L x 2 in. W. Manifold gas pressure: 3.5 in. W C. Electric requirements: 115 V, 60 Hz, 1 amp, 1 phase. Jacket inlet/outlet: 1 in. threaded female. Overall dimensions: 36 in. L x 28 in. W x 35 in. H.(ACN147).
1991 Groen Gas-Fired Jacketed Kettle-10 Gallon. Model: TDH/40. NB & S/N: 22201. MAWP: 50 psi @ 300 °F, MDMT: 50 °F @ 50 psi. The Groen Model TDH 40 quart has stainless steel construction, self-contained, steam jacketed unit operating from a gas heated steam. Typical applications: browning meats, sauces, vegetables, seafood, soups, rice, pasta, stews, pie fillings, reheating cook-chill & prepared foods. Main burner operation/system includes: thermostat, pressure gauge, gas regulator valve, heating indicator lamp, on/off switch, front mounted water level sight glass: 1-1/4 in dia. Natural gas, input rate: 1.55 hp (boiler) (52000 BTU/hr) with (12) burners. Steam outlet: 17 in. L x 2 in. W. Manifold gas pressure: 3.5 in. W C. Electric requirements: 115 V, 60 Hz, 1 amp, 1 phase. Jacket inlet/outlet: 1 in. threaded female. Overall dimensions: 36 in. L x 28 in. W x 35 in. H.
Groen Gas-Fired Jacketed Kettle- 5 Gallon. Model: TDH/20. NB & S/N: 31716. Stainless steel. MAWP: 50 psi @ 300 °F, MDMT: 50 °F @ 50 psi. The Groen Model TDH 20 quart is a self-contained, steam jacketed unit operating from a gas heated steam. Typical applications: browning meats, sauces, vegetables, seafood, soups, rice, pasta, stews, pie fillings, reheating cook-chill & prepared foods. Main burner operation/system includes: thermostat, pressure gauge, gas regulator valve, heating indicator lamp, on/off switch. Front mounted water level sight glass: 1-1/4 in dia. Natural gas, input rate: 0.92 hp (boiler) (31000 BTU/hr) with (8) burners. Manual tilt mechanism. Steam outlet: 15-1/2 in. L x 2 in. W. Manifold gas pressure: 3.5 in. W C. Electric requirements: 115 V, 60 Hz, 1 amp, 1 phase. Jacket inlet/outlet: (2) 1 in. threaded female. Overall dimensions: 34 in. L x 26 in. W x 31 in. H.
1991 Groen Gas-Fired Jacketed Kettle- 5 Gallon. Model: TDH/20. NB & S/N: 23836. Stainless steel. MAWP: 50 psi @ 300 °F, MDMT: 50 °F @ 50 psi. The Groen Model TDH 20-quart is a self-contained, steam jacketed unit operating from a gas heated steam. Typical applications: browning meats, sauces, vegetables, seafood, soups, rice, pasta, stews, pie fillings, reheating cook-chill & prepared foods. Main burner operation/system includes: thermostat, pressure gauge, gas regulator valve, heating indicator lamp, on/off switch. Front mounted water level sight glass: 1-1/4 in dia. Natural gas, input rate: 0.92 hp (boiler) (31000 BTU/hr) with (8) burners. Steam outlet: 15-1/2 in. L x 2 in. W. Manifold gas pressure: 3.5 in. W C. Electric requirements: 115 V, 60 Hz, 1 amp, 1 phase. Jacket inlet/outlet: (2) 1 in. threaded female. Overall dimensions: 34 in. L x 26 in. W x 31 in. H.
1990 Vulcan Hart Steam Jacketed Kettle-125 Gallon. Model: GT125E. S/N: 900223976C. Nat'l Bd: 22075. Natural gas-fired. Input per burner: 0.44 hp (15000 BTU/hr). Total: 4.0 hp (135000 BTU/hr). MAWP: 15 psi at 250 °F. System requirements: 115 V, 60 Hz, 2.6 amps, single phase. Kettle has a sloped bottom with open top and flip-top lid. Inlets: (1) 1/2 in. dia. NPT (female), open top. Outlets: (1) 1/2 in. dia. NPT (female), (1) 3 in. dia. valve (tank discharge), (1) 9-3/4 in. L x 4 in. W (vapor). Overall dimensions: 46 in. diameter x 58 in. H.
Cleveland Gas Kettle-40 Gallon. Model: KGM-40. NB: 17882. S/N: T6761-88E-05. MAWP: 25 psi at 267 °F. Variable temperature control, low water level sight glass, and cold/hot water valve. Pressure gauge: 0-60 psi. Inlets: (1) 1 in. dia. (jacket). Outlets: (1) 1 in. dia. (jacket), (1) 1-1/4 in. dia. (discharge). Overall dimensions: 35 in. L x 31 in. W x 45 in. H.
Market Forge Gas-Fired Steam Jacketed Kettle- 30 Gallon. Model: MF-30. S/N: 32140. Nat'l Bd: 4128. MAWP @ 300 °F: 40 psi. Maximum temperature: 300 °F. Inner shell thickness: 0.071 in. Outer shell thickness: 0.062 in. Inner shell radius: 11.50 in. Outer shell radius: 11.75 in. Kettle is mounted in an enclosed cabinet base. Inlets: (1) 1/2 in. dia. FNPT (jacket), (1) 1 in. dia. port (gas). Outlets: (1) 1/2 in. dia. FNPT (jacket), (1) 1 in. dia. FNPT valve, (1) 4 in. dia. vent. Overall dimensions: 34 in. L x 28-1/2 in. W x 40 in. H.
Groen Steam Jacketed Kettle- 40 Gallon. Model: AH/1-40. S/N: 130D. Nat'l Bd: 69075. Gas-fired: natural or propane. MAWP @ 300 °F: 45 psi. Input rate: 100,000 Btuh. Open top with lift-top lid. Natural gas feed rate (min/max): 4.5/14 in. W.C. Features include: 180 emery grit finished interior, thermostatically controlled shut off. Great for chain restaurants, supermarkets, schools, and healthcare facilities. Electrical requirements: 115 V, 1 amp, 60 Hz, single phase. Inlets: (1) 3/4 in. dia. NPT (male, jacket), (1) 3/4 in. dia. NPT (male, natural gas), (1) 4 in. dia. pilot access door. Outlets: (1) 3/4 in. dia. NPT (female, jacket), (1) 1-1/2 in. dia. discharge, (1) 6 in. dia. exhaust port. Overall dimensions: 40 in. L x 38 in. W x 43 in. H.
Groen Steam Jacketed Kettle- 40 Gallon. Model: AH/1E-40. S/N: 122028. Nat'l Bd: 122028. Gas-fired: natural. MAWP: 30 psi at 300 °F. Input rate: 100,000 Btu/h. Open top with lift-top lid. Natural gas feed rate (min/max): 4.5/14 in. W.C. Features include: 180 emery grit finished interior, thermostatically controlled shut off. Great for chain restaurants, supermarkets, schools, and healthcare facilities. Electrical requirements: 115 V, 1 amp, 60 Hz, single phase. Sight glass level, pressure gauge, Inlets: 1 in. threaded (male), natural gas inlet: 3/4 in. diameter NPT. Outlets: (1) 3/4 in. dia. NPT (female, jacket), tank discharge: (1) 2 in. threaded (male), exhaust port/steam outlet: 6 in. diameter. Overall dimensions: 40 in. L x 34 in. W x 44 in. H.
Royce L. Parker Inc. Gas-Fired Steam Jacketed Kettle- 13 Gallon
Mfg: Royce L. Parker Inc.
Model:GKSH13
Stock No. SPPP631.a
Serial: 3546
Royce L. Parker Inc. Gas-Fired Steam Jacketed Kettle- 13 Gallon. Model: GKSH13. S/N: 3546. Inlets: (1) 1/2 in. dia. pipe (gas), (1) 1-1/2 in. dia. pipe (water). Outlets: (1) 3/4 in. dia. FNPT, (1) 1-1/2 in. dia. discharge, (1) 4 in. dia. vent. Overall dimensions: 27 in. L x 25 in. W x 40 in. H.
Wear-Ever Aluminum Gas Fired Kettle- 20 Gallon. Typical applications: meat dishes, vegetables, soups, sauces, pasta, rice, potatoes, pie fillings, gravies, poultry, seafood, boiling bagels. Pilot system for easy start-up. Flip-top cover. (2) Gas control valves. Easy to clean, removable tank. Inlets: (1) 1 in. dia. NPT (male, gas). Outlets: (1) 1-1/2 in. threaded (male, tank discharge), (1) 4 in. diameter vent. Overall dimensions: 28 in. diameter x 39 in. H.
Vulcan-Hart Gas Heated Kettle- 40 Gallon. Model: GKSH-40. S/N: 6776. Interior bottom sloped to front for smooth product flow through a mounted, tapered, plug type food draw-off valve. Inside dimensions: 30 in. dia. x 14-1/2 in. H. Inlets: (1) 3/4 in. dia. NPT (female, gas), (1) 4-1/2 in. dia. (kettle). Outlets: (1) 3/4 in. dia. (pressure read-out and pressure relief valve), (1) 1-1/2 in. dia. (kettle), (1) 5-3/4 in. dia. exhaust duct. Overall dimensions: 40 in. L x 38 in. W x 39 in. H.
1990 Vulcan-Hart Gas Kettle-125 Gallon. NB: 22073. S/N: 239740. Stainless steel body. MAWP: 15 psi. @ 200 °F, MDMT: 0°F @ 15 psi. Vulcan temperature control, Model: GT125E, burner: 0.44 hp (boiler) (15000 BTU/hr), total: 4 hp (boiler) (135000 BTU/hr)., manifold pressure: 3.5 psi. Electrical control requirements: 115 V, 2.6 amps, 60 Hz, 1 phase. Level indicator. Tank discharge: 3 in. diameter valve, steam outlet: ¾ in. expansion to 2-1/2 in. diameter pvc pipe, heat outlet: 10 in. L x 4 in. W., relief valve: 1 in. threaded male, jacket inlet/outlet: (2) 1 in. threaded male. Overall dimensions: 50 in. L x 49 in. W x 55 in. H.
SOLD
SOLD Groen Gas Fired Steam Jacketed Kettle- 60 Gallon SOLD
Mfg: Groen
Model:H60
Stock No. SPPP595.3a
Serial: 631 K
Groen Steam Jacketed Kettle- 60 Gallon. Stainless steel. Model: H60. S/N: 631 K. Gas-fired: natural or propane. MAWP @ 300 °F: 30 psi. Input rate: 135,000 Btuh. Electrical requirements: 115 V, 60 Hz, single phase. Open top with piston-assist lift-top lid. Features include: 180 emery grit finished interior, thermostatically controlled shut off. Inlets: (1) 3/4 in. dia. NPT (male, jacket), (1) 3/4 in. dia. NPT (male, natural gas), (1) 4 in. dia. pilot access door. Outlets: (1) 1 in. dia. NPT (female, jacket), (1) 1-1/2 in. dia. discharge, (1) 6 in. dia. exhaust port. Overall dimensions: 40 in. L x 38 in. W x 43 in. H. Overall dimensions: 46 in. L x 44 in. W x 51-1/2 in. H. Great for chain restaurants, supermarkets, schools, and healthcare facilities.
SOLD
SOLD 1997 Cleveland Gas-Fired Steam Jacketed Kettle- 100 Gallon SOLD
Mfg: Cleveland
Model:KGL-100
Stock No. SPPP588.5a
Serial: WT9993-97L01
1997 Cleveland Gas-Fired Steam Jacketed Kettle- 100 Gallon. Model: KGL-100. S/N: WT9993-97L01. Nat'l Bd: 49795. 316 stainless steel construction. Capacity: 5.68 boiler hp (190,000 BTUh). Natural gas. Jacket MAWP @ 298 °F: 50 psi. Jacket MDMT @ 50 psi: 33 °F. Electrical requirements: 120 V, 10 amps, 60 Hz, single phase. Key features include: 2/3 steam jacketed, power burner heating system, insulated heat exchanger, infinite variable temperature control, and indicators for heat cycle and low water warning. Inlets: (1) 1/2 in. dia. NPT (female, gas), (1) 3/4 in. dia. NPT (male, jacket). Outlets: (1) 1/2 in. dia. NPT (male, jacket), (1) 5 in. L x 4 in. W vent. Inside dimensions: 35-1/2 in. D. x 21 in. H. Overall dimensions: 44 in. L x 40 in. W x 54 in. H.
SOLD
SOLD 1998 Cleveland Gas Tilting Kettle- 40 Gallon SOLD
Mfg: Cleveland
Model:KGL-40T
Stock No. SPPP621.5
Serial: WT0360-98B-01
1998 Cleveland Gas Tilting Kettle- 40 Gallon. Model: KGL-40T. S/N: WT0360-98B-01. NB: 50311. 2/3 Steam jacketed self contained stationary gas. Steam jacket permanently filled with treated, distilled water. Venting and refilling not required. Precise, consistent temperature control: less than 2 °F variance. Operating temperature range: 145 - 260 °F. Solid state controls, for temperature, low water safety, and power on/off switch. Energy efficient (65%) high performance gas-fired heating system for fast heat-up and recovery time. Horse power Input: 4.18 hp (boiler) (140,000 BTU). Natural gas, supplied with gas pressure regulator. Splash-proof front mounted pressure/vacuum gauge. Safety valve mounted toward rear of kettle. Automatic-electronic spark ignition system. Tilt mechanism on roller bearings and case hardened self-locking worm and segment gear. MAWP: 50 psi @ 298 °F, MDMT: 33 °F @ 50 psi. Electrical requirements: 120 V, 10 amps, 1 phase, 60 Hz. Jacket inlet/outlet: (2) 1 in. diameter. Tank discharge: 2 in. diameter, steam outlet: 6 in. L x 4-1/2 W. Overall dimensions: 47 in. L x 41 in. W x 46 in. H.
SOLD Groen Gas-Fired Steam Jacketed Kettle- 80 Gallon
Mfg: Groen
Model:AH/1-80
Stock No. SPPP620.5a
Serial: 678B
Groen Gas-Fired Steam Jacketed Kettle- 80 Gallon. Model: AH/1-80. S/N: 678B. Nat'l Bd: 64106. MAWP: 360 psi at 300 °F. Input rate: 4.3 boiler hp (145000 BTU/hr). Type of gas: natural. System requirements: 115 V, 60 cycles, 2 amps, 1 phase. Complete with sight glass and pressure as well pilot access through a circular door. as gauge. Typical applications: meat dishes, vegetables, soups, sauces, pasta, rice, potatoes, pie fillings, gravies, poultry, seafood, boiling bagels. Gas. Inlet: 1/2 in. NPT connection. Outlets: 6-1/2 in. diameter vent. Overall dimensions: 38 in. L x 45 in. W x 58 in. H.
SOLD
1991 Vulcan-Hart Gas Kettle- 80 Gallon. S/N: 27-170932. MAWP: 15 psi @ 250 °F, MDMT: 0 °F @ 15 psi. Temperature control, model: GL80E, S/N: 27170932. Input hp per burner (boiler): 0.44 hp (15000 BTU/hr), total (boiler): 4 hp (BTU/hr: 135000). Manifold pressure: 3.5 psi.; Gauge: 0-30 psi. Control requirement: 120 V, 2.6 amps, 60 Hz, 1 phase. Tank opening: 3 in. valve. Overall dimensions: 48 in. L x 43 in. W x 43 in. H.
Cleveland Gas Fired Steam Jacketed Kettle- 80 Gallon. Model: KGM-80. S/N: 6106-7G-01. Nat'l Bd: 15158. Stainless steel construction. MAWP: 25 psi at 267 °F. 2/3 jacketed with variable temperature control, low water level sight glass, and cold/hot water valve. Outlets: 1-1/4 in. valve (tank discharge), 6 in. diameter vent. Overall dimensions: 48 in. L x 38 in. W x 48 in. H.
SOLD Cleveland Steam Gas Fired Jacketed Kettle- 60 Gallon SOLD
Mfg: Cleveland
Model:KGM-60
Stock No. SPPP598.3a
Serial: 5944-7E-03
Cleveland Steam Gas Fired Jacketed Kettle- 60 Gallon. Model: KGM-60. S/N: 5944-7E-03. MAWP @ 267 °F: 25 psi. Full jacket. Inlets: (1) 1/2 in. dia. NPT (female, jacket). Outlets: (1) 1/2 in. dia. NPT (female, jacket), (1) 1-1/4 in. dia. pipe, (1) 5 in. dia. vent tube. Overall dimensions: 40 in. L x 34-1/2 in. W x 46 in. H.
SOLD Vulcan Hart Gas-Fired Full-Steam Jacketed Kettle- 60 Gallon SOLD
Mfg: Vulcan Hart
Model:GS60E
Stock No. SPPP601.4a
Serial: 15398
Vulcan Hart Gas-Fired Full-Steam Jacketed Kettle- 60 Gallon. Model: GS60E. S/N: 15398. Nat'l Bd: 8818. Natural gas. Capacity: 4.0 boiler hp (135,000 BTU/hr). Input per burner: 0.44 boiler hp (15,000 BTU/hr). Number of burners: 9. MAWP: 10 psi at 250 ?F. Kettle is equipped with sight glass level indicator, pressure gauge, pressure relief valve, and thermostatic air vent. Sloped bottom. Inlets: (1) 1 in. dia. NPT (male, jacket). Outlets: (1) 1 in. dia. NPT (male, jacket), (1) 3 in. dia. tank discharge valve, 10 in. L x 4 in. W steam exhaust duct. Overall dimensions: 49 in. L x 45 in. W x 41 in. H.
SOLD Vulcan Hart Gas Fully Jacketed Stationary Kettle-60 Gallon SOLD
Mfg: Vulcan Hart
Model:GL60E
Stock No. SPPP600.3a
Serial: 14377
Vulcan Hart Gas Fully Jacketed Stationary Kettle-60 Gallon. Model: GL60E. S/N:14377. NB:7754. Natural gas-fired. Input: 0.44 hp per burner (15000 BTU/hr). (8) burners natural gas system with a total of 3.58 hp (120000 BTU/hr). Kettle features a sight glass level indicator and a sloped bottom. Inlets: (1) 3/4 in. dia. NPT (female), open top. Outlets: (1) 3/4 in. dia. NPT (female), (1) 3 in. dia. valve (tank discharge), (1) 10 in. L x 4 in. W (vapor). Overall dimensions: 55 in. diameter x 45 in. H.
Groen Natural Gas Kettle- 60 Gallon. Model AH 1-60. Nat. BD # 99193.MAWP: 30 psi @ 300 °F. 145000 Btu. Inside dimensions: 30 in. dia. x 24 in. H. Outlet: 1 in. No lid.
SOLD 1990 Vulcan-Hart Natural Gas Braising Pan- 30 Gallon SOLD
Mfg: Vulcan-Hart
Model:G-30-0
Stock No. SPPP345.1a
Serial: 90012955D
1990 Vulcan-Hart Natural Gas Braising Pan- 30 Gallon. Model: G-30-0. S/N: 90012955D. Inside dimensions: 24 in. L x 32 in. W x 9 in. H. Type: natural gas. Manifold pressure: 5 in. W.C. Capacity: 90,000 btu. Electric igniter. Power supply: 150 watts, 115 V, 60 Hz, single phase. Inlets/outlets: (1) 20 in. L x 2 in. with exhaust duct. Overall dimensions: 3ft. L x 2ft. 9 in. W x 3ft. 4 in. H. (ACN110).
SOLD 1997 Groen Gas-Fired Jacketed Kettle - 10 Gallon SOLD
Mfg: Groen
Model:TDH/40 M-2
Stock No. EG01.1a
Serial: 47154
1997 Groen Gas-Fired Jacketed Kettle - 10 Gallon. Model: TDH/40. S/N: 47154. Nat'l Bd: 47154. Stainless steel. MAWP: 50 psi @ 300 °F, MDMT: 32 °F @ 50 psi. The Groen Model TDH 40-quart is a self-contained, steam jacketed unit operating from a gas heated steam. Typical applications: browning meats, sauces, vegetables, seafood, soups, rice, pasta, stews, pie fillings, reheating cook-chill & prepared foods. Stainless steel steam jacket cooks from all sides for faster heat-up and cook times(1) Sight glass. Faucet with hot and cold valves. Overall dimensions: 37 in. L x 30 in. W x 54-½ in. H.(ACN147).