Shell And Tube Heat Exchanger Used Shell And Tube Heat Exchanger Shell And Tube Heat Exchangers Used Shell And Tube Heat Exchangers
> Heat Exchanger > Shell and Tube Heat Exchanger

Shell and Tube Heat Exchanger

Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
1996 Refrigeration Valves and Systems Corp. Shell and Tube Heat Exchanger - 80 Tons
Mfg: Refrigeration Valves and Systems Corp. Model:Precision
Stock No. HDCS244.9 Serial: 96407 and 96408
1996 Refrigeration Valves and Systems Corp. Shell and Tube Heat Exchanger. Model: Precision. S/N's: 96407 and 96408. Nat'l Bd: 9028 and 9029. Capacity: 960,000 btu/hr = 80 tons of refrigeration. Tube material: SA214-ERW. Number of passes: 4. Number of tubes: 180. Tube dimensions: 3/4 in. dia. x 15 ft. L. Heat transfer surface area: approx. 530 sq. ft. Tube volume: 60 gal. Shell side MAWP: 250 psi @ 200 °F. Shell side MDMT: 250 psi @ -20 °F. Tube side MAWP: 100 psi @ 200 °F. Tube side MDMT: 250 psi @ -20 °F. Surge Tank- 85 Gallon, inside straight-wall dimensions: 1 ft. 2 in. dia. x 11 ft. L. Inlets: (2) 1-1/4 in. dia. liquid refrigerant feed ports, (1) 4 in. dia. flanged liquid port. Outlets: (1) 3/4 in. dia. liquid drain port, (1) 3 in. dia. refrigerant suction port, (1) 4 in. dia. flanged liquid port. Overall dimensions: 16 ft. 4 in. L x 5 ft. W x 8 ft. 4 in. H. (ACN237)
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
1991 Atlas Shell and Tube Heat Exchanger
Mfg: Atlas Model:
Stock No. RPAG641C.23 Serial: 4653
1991 Atlas Shell and Tube Heat Exchanger. S/N: 4653. Nat'l Bd: 3442. Tube material: 316 stainless steel. Number of passes: 1. Number of tubes: 76. Tube dimensions: 1/2 in. dia. x 8 ft. L. Heat transfer surface area: approx. 79 sq. ft. Tube volume: 6 gal. Shell side MAWP: 150 psi @ 350°F. Tube side MAWP: 150 psi @ 350°F. Inlets: (1) 3 in. dia., 4-bolt flanged port (media), (1) 6 in. dia., 4-bolt flanged port (product). Outlets: (1) 3 in. dia., 4-bolt flanged port (media), (1) 6 in. dia., 4-bolt flanged port (product). Overall dimensions: 2 ft. 5-1/2 in. L x 2 ft. 5 in. W x 11 ft. 5 in. H. (ACN172).
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Stainless Steel 5-Pass Shell and Tube Heat Exchangers
Mfg: Model:
Stock No. DTTC2013. Serial:
(3) Stainless Steel 5-Pass Shell and Tube Heat Exchangers. (153) 1-1/2 in. dia. x 20 ft. L multi-tubes. Heat transfer surface area: approx. 1200 sq. ft. Front cover thickness: 1 in. Wall thickness: 0.055 in. Inlets: (1) 6 in. dia. product port, (1) 10 in. dia. media flanged port. Outlets: (1) 6 in. dia. product port, (1) 10 in. dia. media flanged port. Overall dimensions: 22 ft. 1 in. L x 3 ft 10 in. W x 9 ft. H. FAD
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Bingley Stainless Steel Works Shell and Tube Heat Exchanger
Mfg: Bingley Stainless Steel Works Model:F0362.5
Stock No. SNCC121.11a Serial: 209
Bingley Stainless Steel Works Shell and Tube Heat Exchanger. Model: F0362.5. S/N: 209. Material specifications: SA240 304 SS. Number of passes: 6. Number of tubes: 48. Tube dimensions: 1 in. dia. x 9 ft. L. Heat transfer surface area: 100 sq. ft. Tube volume: 17.6 gallon. Shell side MAWP: 80 psi @ 150 °F. Tube side MAWP: 50 psi @ 150 °F. Shell thickness: 3/16 in. Kunkle 2 in. Pressure Relief Valve, set pressure: 85 psi. Inlets: (1) 2 in. dia. NPT (male, jacket), (1) 2 in. dia. port with a 6 in. flange. Outlets: (1) 2 in. dia. tube (jacket), (1) 2 in. dia. port with a 6 in. flange. Overall dimensions: 10 ft. 9-1/2 in. L x 2 ft. 2 in. W x 5 ft. 4 in. H. (ACN585).
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Hot Water Set with Shell and Tube Heat Exchanger
Mfg: Model:
Stock No. SPGP030.3 Serial:
Shell and tube hot water set with Armstrong shell and tube heat exchanger surge tank, and pump trap. Tank: National board number 77591. MAWP 125 psi at 240 °F. MAWP 861 KPA at 115 °C. MDMT 18 °F at 125 PSI. Size 60. Year built 1999. Armstrong heat exchanger certified by S.A. Armstrong limited. Tube Side: 150 psi, 375 F, 150 psi. Shell Side: 150 psi, 375 F, 35 F, 150 psi. S/N 101204, Model S-64-2-2. Year Built 1998. Surge Tank: Max Pressure 160 psi, Max temp: 350 °F. Armstrong Pump: Model 2X1X10 4280. Pump Capacity: 35, US GPM 80 ft. Motor 3 hp, 1,800 rpm, Tag: IMP DIA 8.897. Pressure gauge 100 psi.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Stainless Steel Essence Recovery System
Mfg: Model:
Stock No. CCFP526. Serial:
Stainless Steel Essence Recovery System. System is used to "strip" feed juices of their flavor by evaporation and to "concentrate" these esters in a distillation column. System consists of a reboil u-tube, with a reboil rate of 328 lbs/hr, connected to an 11-1/2 in. inner dia x 17 ft. H essence column for fruit juice concentration. A Whitlock Hi-Transfer shell and tube heat exchanger/condenser, with (222) 5/16 in. dia. x 36 in. L tubes and 65.9 sq. ft. of surface area, is designed to keep condensate temperature as near to boiling as possible (212 F). Another Whitlock Hi-Transfer shell and tube heat exchanger with (84) 5/16 in. dia. x 36 in. L tubes and 24.7 sq. ft. of surface area, is used as a condenser/vent cooler and is designed to cool non-condensibles to within 15-20 F of water temperature. Last, an essence cooler, with (12) 1-3/8 in. dia. x 15 ft. L tubes, transmits the essence to the concentrate. Overall dimensions: 10 ft. L x 5 ft. W x 24 ft. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
APV Essence Recovery System
Mfg: APV Model:
Stock No. 35.D01a Serial:
APV Essence Recovery System. Includes 30 foot distillation column, ceramic saddle distillation column with essence recover. Inlets/outlets: 8-1/2 in. at top, 9-1/2 in. & 4 in. on one side. Overall height is 46 ft.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
2000 Enerquip Twin Shell and Tube Heat Exchanger System
Mfg: Enerquip Model:NEUC
Stock No. MFBB359a.0 Serial: 3128 and 3129
2000 Enerquip Twin Shell and Tube Heat Exchanger System. Model: NEUC. S/N’s: 3128 and 3129. Nat’l Bd: 3327 and 3326. Tube material: 304 stainless steel. Number of passes: 2. Number of tubes: 32. Tube dimensions: 1/2 in. dia. x 2 ft. 7 in. L. Heat transfer surface area: approx. 10 sq. ft. Shell diameter: 6-1/2 in. Shell and tube side MAWP: 150 psi @ 375 °F. Shell and tube side MDMT: 150 psi @ -20 °F. Meters/controls: (4) Worcester Actuators, Series 39, (6) Fischer Pneumatic Actuators, Model 1-1/4 in., (2) El-O-Matic Actuators, Type: ESA-65-4/A. Inlets: (1) 3 in. dia. NPT (jacket), (1) 2 in. dia. NPT. Outlets: (1) 1-1/2 in. dia. NPT (jacket), (1) 2 in. dia. NPT. Overall dimensions: 6 ft. 4 in. L x 3 ft. in. W x 6 ft. 5 in. H. (ACN40)
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Atlas Shell and Tube Heat Exchanger
Mfg: Atlas Model:
Stock No. RPAG687.91 Serial:
Atlas Shell and Tube Heat Exchanger. Heating transfer surface area: 239 sq. ft. Number of tubes: 229. Tube dimensions: 1/2 in. dia. x 96 in. L. Inlets/outlets: 4 in. dia., 4-bolt flanged ports. Overall dimensions: 25-1/2 in. L x 24-1/2 in. W x 96 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Bas-Tex Shell and Tube Heat Exchanger
Mfg: Bas-Tex Model:
Stock No. PSNA002. Serial: 4716-84-1
Bas-Tex Shell and Tube Heat Exchanger. S/N: 4716-84-1. Nat'l Bd: 4297. Shell side MAWP: 300 psi @ 300 °F. Tube side MAWP: 1000 psi @ 200 °F. Inlets: (2) 4 in. dia. ports. Outlets: (2) 4 in. dia. ports. Overall dimensions: 29 in. L x 19 in. W x 8 ft. 4 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
1991 RW Holland Company Shell and Tube Heat Exchanger
Mfg: RW Holland Company Model:
Stock No. PSNA004. Serial: 94-4714
1991 RW Holland Company Shell and Tube Heat Exchanger. S/N: 94-4714. Heat transfer surface area: approx. 147 sq. ft. Number of tubes: 22. Tube dimensions: 3/4 in. dia. x 34 ft. 2 in. L. Shell side MAWP: 1000 psi @ 200 °F. Tube side MAWP: 1000 psi @ 200 °F. Shell side MDMT: 0 °F @ -20 psi. Tube side MDMT: 100 °F @ 1000 psi. Inlets: (1) 6 in. dia., 8-bolt flanged port. Outlets: (1) 6 in. dia., 8-bolt flanged port. Overall dimensions: 16 ft. 2 in. L x 31 in. W x 31 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
1992 Ketema Inc. Heat Transfer Division DXMB Shell and Tube Heat Exchanger
Mfg: Ketema Inc. Model:607-Q-SP-1C
Stock No. LCNM006. Serial: U9224129
1992 Ketema Inc. Heat Transfer Division DXMB Shell and Tube Heat Exchanger. Model: 607-Q-SP-1C. S/N: U9224129. P/N: 410-00200-002. Nat'l Bd: 5402. Tube material: carbon steel. Number of passes: 4. Number of tubes: 55. Tube dimensions: 1/2 in. dia. x 7 ft. L. Heat transfer surface area: 50.4 ft. sq. Tube volume: 4 gal. MAWP shell side: 300 psi @ 200 °F. MDMT shell side: -20°F @ 300 psi. MAWP tube side: 300 psi @ 300°F. MDMT tube side: -20°F @ 300 psi. Inlets: (1) 1/2 in. dia. product feed, (1) 1-1/2 in. dia. media feed. Outlets: (1) 3/4 in. dia. media discharge, (1) 3/4 in. dia. media drain, (1) 1 in. dia. bevel with hex safety relief, (1) 1-1/4 in. dia. product discharge. Overall dimensions 4 ft. L x 1 ft. 2 in. W x 10 ft. 7 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Atlas Shell and Tube Heat Exchanger
Mfg: Atlas Model:
Stock No. RPAG688. Serial:
Atlas Shell and Tube Heat Exchanger. Tube material: 316 stainless steel. Number of tubes: 229. Tube dimensions: 1/2 in. dia. x 8 ft. L. Heat transfer surface area: approx. 239.68 sq. ft. Tube volume: 18.5 gal. Inlet: (1) 4 in. dia. flanged port. Outlet: (1) 4 in. dia. flanged port. Overall dimensions: 2 ft. 1-1/2 in. L x 2 ft. 1/2 in. W x 8 ft. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Atlas Shell and Tube Heat Exchanger
Mfg: Atlas Model:
Stock No. RPAG689. Serial: 4650
Atlas Shell and Tube Heat Exchanger. S/N: 4650. Nat'l Bd: 3416. Tube material: 316 stainless steel. Number of tubes: 76. Tube dimensions: 1/2 in. dia. x 8 ft. L. Heat transfer surface area: approx. 79.5 sq. ft. Tube volume: 6 gal. Shell side MAWP: 150 psi @ 350°F. Tube side MAWP: 150 psi @ 350°F. Inlet: (1) 3 in. dia. flanged port. Outlet: (1) 3 in. dia. flanged port. Overall dimensions: 8 ft. L x 1 ft. 8 in. W x 2 ft. 1-1/2 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
2000 E.L. Nickell Ammonia Subcooler
Mfg: E.L. Nickell Model:
Stock No. DTTC004B. Serial: S008669
2000 E.L. Nickel Ammonia Subcooler. S/N: S008669. Nat'l Bd: 47629. Job No: C-14191-B. MAWP: 250 psi @ 225 °F. MDMT: -20 °F @ 250 psi. Tube material: 304 stainless steel. Number of passes: 4. Number of tubes: 460. Tube dimensions: 9/16 in. dia. x 8 ft. L. Heat transfer surface area: approx. 542 sq. ft. Tube volume: 47 gal. (4) Cyrus Shank Pressure Relief Valves, Types: 804 and 804TH*, inlet: 3/4 in., set pressure: 250 psig, air capacity: 880 and 791* scfm. Inlets: (1) 10 in. dia. port. Outlets: (3) 6 in. dia. ports. Overall dimensions: 14 ft. 10 in. L x 48 in. W x 98 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Brown Fintube Company Heat Exchanger
Mfg: Brown Fintube Company Model:
Stock No. PSNA001. Serial:
Brown Fintube Company Heat Exchanger. S/N: 8621-89-1. Nat'l Bd: 7874. Heat transfer surface area: 98 sq. ft. Number of tubes: 38. Tube dimensions: 1/2 in. dia. x 17 ft. 2 in. L. Shell side MAWP: 1440 psi @ 200 °F. Shell side MDMT: 20 °F @ 1440 psi. Tube side MAWP: 1440 psi @ 250 °F. Tube side MDMT: 20 psi @ 1440 °F. Inlets/outlets: 7 in. dia. flanged ports with (12) 1/2 in. dia. thru-holes. Overall dimensions: 42 in. L x 19 in. W x 93-1/2 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Chester Jensen Heat Exchanger
Mfg: Chester Jensen Model:
Stock No. 120.TR-376-A Serial:
Chester Jensen Heat Exchanger. Model SV-20, S/N n/a. 24/ea x 10 ft. long by 1-1/2 in. dia. tubes.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Shell and Tube Heat Exchanger
Mfg: Model:0-44554
Stock No. CJRP5186.2 Serial: SU-85-2
Shell and Tube Heat Exchanger. Model: 0-44554. S/N: SU-85-2. Nat'l Bd: 560585. MAWP @ 350 °F: 150 psi. Number of tubes: 22. Tube diameter: 11/16 in. Length of multi-tubes: 60 in. Inlets: (1) 2 in. dia. pipe (media), (1) 3 in. dia. Q-line fitting (product). Outlets: 1-1/4 in. dia. pipe outlet (media), (1) 3 in. dia. Q-line fitting (product). Overall dimensions: 66 in. L x 33 in. W x 12 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Refrigeration Valves and Systems Shell and Tube Heat Exchanger
Mfg: RVS Model:
Stock No. DTTC2034. Serial:
Refrigeration Valves and Systems Shell and Tube Heat Exchanger. Tube material: 304 stainless steel. Number of passes: 1. Number of tubes: 90. Tube dimensions: 1 in. dia. x 12 ft. L. Heat transfer surface area: approx. 282 sq. ft. Tube volume: 44 gal. (3) MSA Gate Valves, body: WCB, stem: CR13, disc: CR13, ANSI 300, maximum temperature: 800 °F. Dresses Pneumatic Steam Control Valve, Model: 30-30242, S/N: B127568-1-2, size: 10 in., ANSI 300, minimum CV: 250, maximum CV: 620, body: carbon steel, plug: 316 SS, seat: 316 SS, shaft: 17-4PHSS, supply: 35 psi. Inlets: (1) 10 in. dia. port (steam), (1) 10 in. dia. 150lb ANSI flanged port (product). Outlets: (1) 10 in. dia. 300lb ANSI flanged port (steam), (1) 10 in. dia. 150lb ANSI flanged port (product). Overall dimensions: 14 ft. 4 in. L x 3 ft. 10 in. W x 10 ft. 3 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Stainless Steel Shell and Tube Heat Exchangers
Mfg: Model:
Stock No. OI160. Serial:
(4) Stainless Steel Shell and Tube Heat Exchangers. (1) 3 in. dia. I-line shell tube with (19) 5/16 in. dia. multi-tubes, each 20 ft. long. ~31 sq. ft. (1) 3-1/2 in. dia. I-line shell tube with (19) 5/16 in. dia. multi-tubes, each 20 ft. long. ~31 sq. ft. (1) 4-1/2 in. dia. I-line shell tube with (31) 5/16 in. dia. multi-tubes, each 20 ft. long. ~51 sq ft. (1) 4-1/2 in. dia. I-line shell tube with (24) 5/16 in. dia. multi-tubes, each 20 ft. long. ~39.25 sq ft.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Precision Heat Exchanger Co. Shell and Tube Heat Exchanger
Mfg: Precision Heat Exchanger Co. Model:
Stock No. DTTC2022. Serial:
(8) Precision Heat Exchanger Co. Shell and Tube Heat Exchangers. S/N's: 11799-5, 11799-6, 11799-7, 11799-8, 11799-9, 11799-10, 11799-11, 11799-12. Nat'l Bd's: 5160, 5161, 5162, 5163, 5164, 5165, 5166, 5167. Tube material: 316 stainless steel. Number of passes (through exchanger group): 4. Number of tubes: 186. Tube dimensions: 1/4 in. dia. x 20 ft. L. Heat transfer surface area: approx. 243 sq. ft. Tube volume: 9.5 gal. Shell side MAWP: 150 psi @ 200 °F. Inlets: (1) 4 in. dia. port (product), (1) 4 in. dia. port (media). Outlets: (1) 4 in. dia. port (product), (2) 4 in. dia. ports (media). Overall dimensions: 23 ft. 10 in. L x 5 ft. W x 8 ft. 11 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
1998 Vilter Shell and Tube 18 ft. Ammonia Heat Exchanger
Mfg: Vilter Model:
Stock No. HDCD367.7 Serial: H73946-1
1998 Vilter Shell and Tube 18 ft. Ammonia Heat Exchanger. S/N: H73946-1. Nat'l Bd: 41337. Number of passes: 4. Number of tubes: 121. Tube material: SA-124 carbon steel. Tube dimensions: 1-1/4 in. dia. x 18 ft. Heat transfer surface area: approx. 712 sq. ft. Shell side MAWP @ 400 °F: 300 psig. Shell side MDMT @ 300 psig: -20 °F. Tube side MAWP @ 200 °F: 75 psig. Tube side MDMT @ 75 psig: -20 °F. Heat exchanger is equipped with Hansen pressure relief valves. Inlets: (1) 3-1/2 in. dia. pipe (media), (1) 4 in. dia. pipe (product) with an 8-1/2 in. dia. flange and (8) 3/4 in. dia. attachment holes at a center-to-center distance of 6-1/2 in. Outlets: (1) 2 in. dia. Pipe (media), (1) 4 in. dia. pipe (product) with an 8-1/2 in. dia. flange and (8) 3/4 in. dia. attachment holes at a center-to-center distance of 6-1/2 in. Shell: 20 in. dia. x 18 ft. L. Overall dimensions: 19 ft. L x 28 in. W x 70 in. H. (ACN250)
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
1994 KHS Ziemann-Liess Shell and Tube Heat Exchanger
Mfg: KHS Ziemann-Liess Model:
Stock No. BIIR7007. Serial: 270132
1994 KHS Ziemann-Liess Shell and Tube Heat Exchanger. S/N: 270132. 304/ A-516 stainless and carbon steel construction. Number of tubes: 104. Tube dimensions: 3/4 in. dia. x 156 in. L. Outer tube diameter 0.997 in. Heat transfer surface area: approx. 357 sq. ft. Volume: approx. 41 gal. Shell side MAWP: 230 psi. Tube side MAWP: 100 psi. MDMT: 24.8 °F. Refrigerant Receiver Tank- 450 Gallon. Inlets: (1) 3 in. dia. threaded fitting (product), (1) 6 in. dia. media port with a 12 in. dia. flange and (8) 1 in. dia. thru holes at a center-to-center distance of 3-3/4 in. Outlets: (2) 1 in. dia. media discharge ports each with a 2-bolt flange with 1/2 in. dia. thru holes at a center-to-center distance of 2-3/4 in., (1) 1-1/2 in. dia. media discharge port with a 4 in. L x 4 in. W flange and (4) 1/2 in. dia. thru holes at a center-to-center distance of 2-1/2 in., (1) 3 in. dia. threaded fitting (product). Overall dimensions: 16 ft. 2 in. L x 56 in. W x 10 ft. 2 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Vilter Shell and Tube Chiller with Surge Drum
Mfg: Vilter Model:
Stock No. DTTC2057. Serial: B-69146-1
Vilter Shell and Tube Chiller with Surge Drum. S/N: B-69146-1. Nat'l Bd: 11.270. Ins: LMC-11.270V. Number of passes: 4. Number of tubes: 518. Tube dimensions: 1 in. dia. x 19 ft. 11-1/2 in. L. Heat transfer surface area: approx. 2,705 sq. ft. Tube volume: 420 gal. MAWP shell side: 200 psi @ 400 °F. Re-rated by Fru-Con Construction Corp., Nat’l Bd: 1173, Date altered: 9/2004. MAWP shell side: 80 psi @ -60 °F. Surge Drum- 615 gallons, inside straight-wall dimensions: 2 ft. 6 in. dia. x 16 ft. 11 in. L. Inlets: (1) 8 in. dia. flanged fitting, (4) 1-1/2 in. dia. ports, (2) 6 in. dia. ports. Outlets: (1) 8 in. dia. flanged fitting, (2) 2 in. dia. ports, (2) 2-1/2 in. dia. ports. Overall dimensions: 22 ft. 5 in. L x 5 ft. 8 in. W x 8 ft. 7 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Bell & Gossett Shell and Tube Heat Exchanger
Mfg: Bell & Gossett Model:SU85-2
Stock No. HDAF869.4 Serial:
Bell & Gossett Shell and Tube Heat Exchanger. Model: SU85-2. Heating surface area: 42 sq. ft. 2-Pass heat exchanger. Test Pressure Tubes: 250 PSI. The “SU” Heat Exchanger is an instantaneous type, designed to heat liquids with steam. No space-wasting, expensive storage tank is needed. Inlets: (1) 2 in. dia. S-Line (product), (1) 2 in. dia. bevel (media). Outlets: (1) 2 in. dia. S-Line (product), (1) 1-1/2 in. dia. port (media) with steam trap. Overall dimensions: 72-1/2 in. L x 14 in. W x 45 in. H. (ACN33).
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
1992 E.L. Nickell Shell and Tube Chiller with Surge Drum
Mfg: E.L. Nickell Model:
Stock No. DTTC2096. Serial:
1992 E.L. Nickell Shell and Tube Chiller with Surge Drum. S/N: 42567. Nat'l Bd: 39724. MAWP shell side: 150 psi @ 200°F. MDMT shell side: -20/-40°F @ 150/60 psi. MAWP tube side: 150 psi @ 200°F. MDMT tube side: -20/-40°F @ 150/40 psi. Re-rated by FruCon Construction Corp., Nat'l Bd: 1173, Date altered: 9/2004, MAWP shell side: 60 psi @ -60°F. 1992 Surge Drum, S/N: 42568, Nat;l Bd: 39725, MAWP: 150 psi @ 200°F, MDMT: -20/-40°F @ 150/60 psi. Inlets: (1) 8 in. dia. flanged fitting, (2) 6 in. dia. ports, (2) 1-1/2 in. dia. ports. Outlets: (1) 8 in. dia. flanged fitting, (1) 1 in. dia. FNPT fitting, (1) 2-1/2 in. dia. port. Overall dimensions: 24 ft. 4 in. L x 6 ft. 5 in. W x 8 ft. 7 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Vilter Ammonia Stainless Steel Tube Chiller with Surge Drum
Mfg: Vilter Model:
Stock No. BIIR8004. Serial:
Vilter Ammonia Stainless Steel Tube Chiller with Surge Drum. Refrigerant: flooded ammonia. Material of construction: 304 stainless steel. Heat exchanger maximum design pressure, shell side: 250 psi @ 200°F, tube side: 75 psi @ 200°F. Hydrostatic test pressure: 375 psi. (156) 1-1/4 in. dia. x 20 ft. L multi-tubes. Heat transfer surface area: approx. 1,020.5 ft. sq. Surge Drum- 260 gallons, straight-wall dimensions: 1 ft. 8 in. dia. x 16 ft. 3 in. L. (2) Parker Float Switches, power supply: 120/240 VAC, 7 amps, pilot duty: 240 VA. Parker Solenoid Valve, S/N: 10816YR02, design pressure: 400 psi, MOPD: 300 psi. (2) Refrigerating Specialty Co. Pressure Regulators, design pressure: 300 psig, range: 75-280 psig. Modular Solenoid Pilot, S/N: V06399, broad view watts: 30. (2) Safety Relief Valves, type: 804, set pressure: 150 psig, capacity air: 546 scfm. Inlets: (1) 3 in. dia. ANSI 150lb flanged port, (1) 4 in. dia. port. Outlets: (2) 1-1/4 in. dia. John Perry fittings (pressure relief), (1) 1-1/2 in. dia. flanged port, (1) 3 in. dia. ANSI 150lb. flanged port. Overall dimensions: 23 ft. L x 3 ft. 6 in. W x 8 ft. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Stainless Steel Heat Exchanger
Mfg: Not Specified Model:
Stock No. SHCA1563.2a Serial:
Stainless Steel Heat Exchanger. 12 in. L x 10 in. W Removable heat exchange insert. Inlets: (4) 1/2 in. dia. NPT (sprayjets), (1) 14 in. dia. infeed with a 17 in. flange. Outlets: (1) 7 in. dia. discharge. Overall dimensions: 20-1/2 in. L x 20-1/2 in. W x 78 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Watlow Industries Heater
Mfg: Watlow Industries Model:F89
Stock No. SHCA1597.1a Serial: 7-10-165-3
Watlow Industries Heater. Model: F89. S/N: 7-10-165-3. Unit specifications: 35 kW, 480 V, 3 phase. Inlets: (1) 2 in. dia. MPT. Outlets: (1) 2 in. dia. tube. Overall dimensions: 113 in. L x 32 in. W x 38 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Dunham-Bush Boiler Feed Pump System
Mfg: Dunham-Bush Model:PCHPD1465
Stock No. HDNW103.4 Serial: 77850
Dunham-Bush Boiler Feed Pump System. Model: PCHPD1468. S/N: 77850. 1994 Cemline Corp. Shell and Tube Heat Exchanger, S/N: 45450, MAWP: 150 psi @ 500°F, MDMT: -20°F @ 150 psi, tube material: carbon steel, number of passes: 3, number of tubes: 237, tube dimensions: 11/16 in. dia. x 9 ft. 6 in. L, heat transfer surface area: approx. 405 sq. ft., tube volume: 43.35 gal. Stoystown Tank and Steel Co. Liquid Storage Tank- 75 Gallon, S/N and Nat'l Bd: 57750, MAWP: 125 psi @ 650°F, MDMT: -20°F @ 125 psi. Centrifugal Pump with Lincoln Electric Motor, 5 hp, 1740 rpm, 230/460 V, 13.6/6.8 amps, 60 Hz, 3 phase. Centrifugal Pump with Baldor Industrial Motor, 5 hp, 1725 rpm, 208-230/460 V, 14.8-14/7 amps, 60 Hz, 3 phase. KSB Italia Centrifugal Pump, Model: G.32-160/054, S/N: 89/170956/1M/91648, capacity: 8 to 65 gpm @ 34.7 to 21.3 tdh. Johnson Controls Pneumatic Valve Positioner, Model: V-5410-4596 9008, Size: 3, Body: cast iron, PN/DN: 250 psi. Johnson Controls Pneumatic Valve Positioner, Model: V-5416-8003 8312, Size: 1-1/2, Body: ductile iron, PN/DN: 10 psi. Condensate Steam Trap, Nat’l Bd: 7667, MAWP: 125 psi @ 375°F, MDMT: -20°F @ 125 psi. Inlets: (1) 4 in. dia. 150lb. ANSI flanged port (product), (1) 8 in. dia. 150lb. ANSI flanged port (media). Outlets: (1) 2 in. dia. 150lb. ANSI flanged port (condensate), (1) 4 in. dia. 15lb. ANSI flanged port (product). Overall dimensions: 11 ft. 10 in. L x 7 ft. W x 7 ft. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Aerco B-plus Indirect- Packed Water Heater
Mfg: Aerco Model:SW1B+09
Stock No. SGML088.1 Serial: H-88-753
Aerco B-plus Indirect- Packed Water Heater. Model: SW1B+09. S/N: H-88-753. National Board: 19512. Style: 110311. MAWP shell 235 psi. at 400°F, spiral tubes 250 psi. at 400°F. Shell thick: 0.188, Head thick: 0.4375. Water heater dimensions: 13-1/2 in. dia. x 48 in. L. Control box with two gauges in the outside; 1st shell outlet, 2nd steam pressure, start/stop indicator, Control box inside components: (2) Gauge from 0 to 30 psi., Limit control set at 20°F minimum above the operating temperature control. Inlets/outlets in the bottom: (2) 3 in. threaded female for the tank, 4 in. threaded female, 2 in. threaded female for the heat spiral tubes. Inlets/outlets in the top: Aqua stat, water solenoid, cutler: 3 in. dia, thermometer line, thermostat, relief valve: 1 in. dia, set 150 psi. at 210°F. Overall dimensions: 24 in. L x 22 in. W x 85 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
G&H Shell and Tube Heat Exchanger
Mfg: G&H Model:T15190
Stock No. HDDF121C.2a Serial: CL30
G&H Shell and Tube Heat Exchanger. Model: T15190. S/N: CL30. Tube material: copper. Number of passes: 2. Number of tubes: 76. Tube dimensions: 1/2 in. dia. x 2 ft. 8 in. L. Heat transfer surface area: 26.5 sq. ft. Tube volume: 2 gal. For steam injected water heating. Inlets: (1) 2 in. dia. NPT (shell, steam), (1) 2-1/2 in. dia. NPT (female, water). Outlets: (1) 1 in. dia. NPT (shell, steam), (1) 2-1/2 in. dia. NPT (female, water). Overall dimensions: 5 ft. 2 in. L x 1 ft. 4 in. W x 4 ft. 7 in. H. (ACN39).
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Nickell Co. Shell and Tube Heat Exchanger
Mfg: Nickell Co. Model:
Stock No. DTTC026. Serial:
Nickell Co. Shell and Tube Heat Exchanger. Nat’l Bd: 28373. Mat’l constr: carbon steel. Number of tubes: 120. Tube dimensions: 1 in. dia. x 12 ft.-1/2 in. L. Heat transfer surface area: approx. 378 sq. ft. Maximum working pressure: 250 psi. Maximum temperature: 300 °F. Minimum temperature: -20 °F. Inlets: (1) 4 in. dia port, (1) 2-1/2 in. dia. port, (1) 3 in. dia. port. Outlets: (1) 2-1/2 in. dia. port. Overall dimensions: 12 ft. 4 in. L x 2 ft. W x 3 ft. 9 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Bell & Gossett Shell and Tube Heat Exchanger
Mfg: Bell & Gossett Model:SU-104-2
Stock No. 38.GOB5471.4 Serial: 89R78807-04-3
Bell & Gossett Shell and Tube Heat Exchanger. Model: SU-104-2. S/N: 89R78807-04-3. Nat’l Bd: 11192. Heat transfer flow rate: 50 gpm. Heating surface area: 56 sq. ft. 2-Pass heat exchanger. Shell side: MAWP: 150 psi @ 375 °F. Shell side MDMT: -20 °F @ 150 psi. Tube side MAWP: 125 psi @ 375 °F. Tube side MDMT: -20 °F @ 125 psi. The “SU” Heat Exchanger is an instantaneous type, designed to heat liquids with steam. No space-wasting, expensive storage tank is needed. Temperature regulator. Fisher Controls Actuator, Size 34, pressure units: psi, maximum allow supply: 90 psi, operation range: 90, travel: 3/4 in., bench set: 9 to 15, body type: GS, size: 2, stem/PWS: 316SST/316SST, rating: 250/100 °F, port size: 2. Conbraco Inc. Steam Relief Valve, S/N: 29.701-38, 5507 lbs/hr. Hoffman Specialty Float & Thermostatic Trap, Model: 592, maximum pressure: 125 psig, size: 2 in. NPT. Inlet: (1) 3 in. dia., 4-bolt flange. Outlets: (1) 3 in. dia., 4-bolt flange, (1) 2 in. dia. NPT (female) port, (1) 1-1/2 in. dia. ACME threaded (male) port. Overall dimensions: 98 in. L x 29 in. W x 85 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Pfaudler Shell & Tube Heat Exchanger
Mfg: Pfaudler Model:
Stock No. CCFP368. Serial:
Pfaudler Shell and Tube Heat Exchanger. Order No: E92468. Tube material: 304 stainless steel. Number of passes: 4. Number of tubes: 64. Tube dimensions: 5/8 in. dia. x 14 ft. L. Heat transfer surface area: approx. 146 sq. ft. Tube volume: 14 gal. Tube side MAWP: 75 psi. Shell side MAWP: 250 psi. Inlets: (1) 2 in. dia. ACME fitting (product), (1) 1-1/4 in. dia. media feed. Outlets: (1) 2 in. dia. ACME fitting (product), (1) 6 in. dia. media discharge. Overall dimensions: 15 ft. 4 in. L x 3 ft. W x 5 ft. 5 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
1997 Bell & Gossett Hot Water Set
Mfg: Bell & Gossett Model:
Stock No. HDAF870.11a Serial:
1997 Bell & Gossett Hot Water Set. Tube material: 316 stainless steel. Number of passes: 2. Number of tubes: 150. Tube dimensions: 3/4 in. dia. x 3 ft. L. Heat transfer surface area: approx. 88 sq. ft. Tube volume: 10 gal. Holding Tank- 20 Gallon, Nat’l Bd: 651167, MAWP: 125 PSI @ 350 F, MDMT: -20 F @ 125 psi. Pump with Baldor Motor 10 hp, 1725 rpm, 208-230/460 V, 28-26/13 amps, 60 Hz, 3 phase. Inlets: (1) 4 in. dia. S-Line (product), (1) 6 in. dia. flanged port (media). Outlets: (1) 1 in. dia. FNPT (media), (1) 4 in. dia. S-Line (product). Overall dimensions: 8 ft. 6-1/2 in. L x 2 ft. 8-1/2 in. W x 4 ft. 8 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
APV 3-Pass Shell and Tube Heat Exchanger
Mfg: APV Model:
Stock No. DBBP2651.2 Serial: 5-160-04-036-005
APV 3-Pass Shell and Tube Heat Exchanger. S/N: 5-160-04-036-005. 16.49 sq. ft. total surface area. 316 Stainless steel shell and tubes. (112) Tubes: 36 in. L x 3/16 in. dia. Shell side MAWP @ 450 °F: 225 psi. Tube side MAWP @ 450 °F: 150 psi. Inlets: (1) 1 in. dia. sanitary fitting, (1) 1-1/2 in. dia. NPT (female, media). Outlets: (1) 1 in. dia. sanitary fitting. (1) 1-1/2 in. dia. NPT (female, media). Overall dimensions: 47-1/2 in. L x 6 in. W.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
1996 ITT Shell and Tube Heat Exchanger
Mfg: ITT Model:
Stock No. DBBP2652. Serial: 96B20022-01
1996 ITT Shell and Tube Heat Exchanger. S/N: 96B20022-01. Shell side MAWP @ 450 °F: 150 psi. Shell side MDMT @ 150 psi: -20 °F. Tube side MAWP @ 300 °F: 150 psi. Tube side MDMT @ 150 psi: -20 °F. Inlets: (1) 1/2 in. dia. sanitary fitting, (1) 1 in. dia. copper bevel fittings (media). Outlets: (1) 1/2 in. dia. sanitary fitting, (1) 1 in. dia. copper bevel fittings (media). Overall dimensions: 52 in. L x 7 in. W x 11 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
1995 Cimco-Lewis Shell and Tube Heat Exchanger
Mfg: Cimco-Lewis Model:
Stock No. HSCI001.45 Serial: 207810
1995 Cimco-Lewis Shell and Tube Heat Exchanger. S/N 207810. Nat'l Bd: 930. Shell side MAWP @ 200 °F: 300 psi. Tube side MAWP @ 150 °F: 150 psi. MDMT @150 psi: -20 °F. Number of tubes: 452. Tube dimensions: 3/4 in. dia. x 191 in. L. Heat transfer surface area: approx. 1,412 sq. ft. System comes with a complete Cimco Refrigeration Control Panel. Refrigerant: R-22. Refrigerant charge: 2,500 lbs. Panel features (2) thermostat controls for (1) ice and (2) brine. Inlets: (1) 8 in. dia. bypass valve, (3) 4 in. dia. pipes (media). Outlets: (1) 3/4 in. dia. pipe with a 2 bolt square flange, (1) 8 in. dia. pipe with 13 in. dia. flange (8) 3/4 in. dia. hole at a center to center distance of 12 in. (452) 3/4 in. dia. x 191 in. L = 1440 sq. ft. Overall dimensions: 17 ft. 9 in. L x 43 in. W x 65 in. H. (ACN571).
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Stainless Steel Shell and Tube Heat Exchanger
Mfg: Model:
Stock No. OI272. Serial:
Stainless Steel Shell and Tube Heat Exchanger. (108) 2 in. dia. x 10 ft. L stainless steel multi-tubes. Heat transfer surface area: approx. 565 sq. ft. Volume: 175 gallon. Inlets: (1) 1-1/2 in. dia. S-line fitting (sprayball), (1) 12 in. dia. flanged port (media), (1) 20 in. dia. flange port (product). Outlets: (1) 2 in. dia. FNPT (media), (1) 2-1/2 in. dia. FNPT (media), (1) 8 in. dia. flanged port (product). Overall dimensions: 4 ft. 8 in. L x 4 ft. W x 15 ft. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Blaw-Knox Shell and Tube Heat Exchanger
Mfg: Blaw Knox Model:
Stock No. TR-273-A Serial: M5241
Blaw-Knox Shell and Tube Heat Exchanger. S/N: M5241. Tube material: 316 stainless steel. Number of passes: 4. Number of tubes: 8. Tube dimensions: 15/16 in. dia. x 10 ft. L. Heat transfer surface area: approx. 19.63 sq. ft. Tube volume: 2.8 gal. Heat exchanger dimensions: 18-3/4 in. diameter x 10 ft. L. (2) Pressure relief valves. Inlets: (1) 15/16 in. dia. S-line fitting, (1) 3-1/2 in. dia. media infeed. Outlets: (1) 15/16 in. dia. S-line fitting, (1) 2 in. dia. FNPT media discharge. Overall dimensions: 11 ft. 3 in. L x 1 ft. 9 in. W x 6 ft. 5 in. H. (XMR15)
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
California Hydronics Skid Mounted Hot Water Set
Mfg: California Hydronics Model:
Stock No. BFLV200.7 Serial:
California Hydronics Skid Mounted Hot Water Set. Heat exchanger dimensions: 10 in. diameter x 61 in. L. (2) Condensate Tanks- 10 Gallon, MAWP: 125 psi at 210 °F. Unit is equipped with (2) electro-pneumatic valves and (2) Jordan pressure relief valves. (2) Bell & Gossett Centrifugal Pumps, Model: 11/28C, MAWP: 175 psi, capacity: 60 gpm at 50 ft, 1800 rpm maximum. (2) Baldor Industrial Motors, 3 hp, 1,725 rpm, 230/460 V, 8.2/4.1 amps, 60 Hz, 3 phase. Inlets: (1) 2 in. threaded fitting(female), (1) 4 in. dia. pipe (steam). Outlets: (1) 2 in. dia. pipe (steam), (1) 2 in. dia. pipe (product). Overall dimensions: 100 in. L x 52 in. W x 85 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
California Hydronics Skid Mounted Hot Water Set
Mfg: California Hydronics Model:
Stock No. BFLV201.7 Serial:
California Hydronics Skid Mounted Hot Water Set. Heat exchanger dimensions: 10 in. diameter x 61 in. L. (2) Condensate Tanks- 10 Gallon, MAWP: 125 psi at 210 °F. Unit is equipped with (2) electro-pneumatic valves and (2) Jordan pressure relief valves. (2) Bell & Gossett Centrifugal Pumps, Model: 11/28C, MAWP: 175 psi, capacity: 60 gpm at 50 ft, 1800 rpm maximum. (2) Baldor Industrial Motors, 3 hp, 1,725 rpm, 230/460 V, 8.2/4.1 amps, 60 Hz, 3 phase. Inlets: (1) 2 in. threaded fitting(female), (1) 4 in. dia. pipe (steam). Outlets: (1) 2 in. dia. pipe (steam), (1) 2 in. dia. pipe (product). Overall dimensions: 100 in. L x 52 in. W x 85 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
1995 Abco Hot Water System
Mfg: Abco Model:
Stock No. cBIIR9001. Serial:
1995 Abco Hot Water System. (2) Bell & Gossett heat exchangers. Material of construction: 316 stainless steel. (196) 5/8 in. dia. x 74-1/2 in. L. multi-tubes. Heat transfer surface area: 200 ft. sq. Volume: 19 gallon. MAWP: 150 psi at 375°F, MDMT: -20°F at 150 psi. Inlets: (2) 6 in. dia. ANSI 150 lb flanged ports, (1) 4 in. dia. ANSI 150 lb flanged ports. Outlets: (2) 2 in. dia. FNPT, (1) 6 in. dia. ANSI 150 lb, (1) 8 in. dia. ANSI 150 lb, (1) 4 in. dia. ANSI 150 lb. (2) Vertiflo centrifugal pumps. Model: 1424. Material of construction: 316 stainless steel. Capacity: 325 gpm @ 160 ft. Size: 4 x 3 x 10. Impeller diameter: 7-1/2 in. U.S. electric motor- 25, 3525 rpm, 230/460 V, 96/48 amps, 60 Hz, 3 phase. Hayward industrial pressurized tank- 25 Gallon. Model: 596 FAB. Maximum pressure: 150. Size: 6. Maximum temperature: 150°F. Sterling electric motor, 1/3 hp, rpm: 1720, 208-230/460 V, 1.25-1.32/0.66 amps, 60 Hz, 3 phase. Regal Beloit Corporation drive, ratio: 300, 5.7 rpm (final). Stainless steel pressurized tank-4 Gallon. Sterling electric motor, model: RBY034 FCA, S/N: 138, 1/3 hp, rpm: 1720, 208-230/460 V, 1.25-1.32/0.66 amps, 60 Hz, 3 phase. Regal Beloit Corporation drive. Ratio: 300, 5.7 rpm (final). (2) centrifugal pumps with Marathon electric motors, 3 hp, rpm: 3475, 208-230/460 V, 8.3-7.8/3.45 amps, 60 Hz, 3 phase. (2) Ronan X-54 Series temperature transmitters. (4) Johnson Controls pneumatic actuators. Overall dimensions: 136 in. L x 96 in. W x 144 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Shell and Tube Heat Exchanger
Mfg: Model:
Stock No. 8.BR-398.2 Serial:
Shell and tube heat exchanger, 316 stainless steel on tube side. 8 square ft., (3) 1 in. x 10 ft. long tubes, vertical, 1 pass, 0A dim = 3-1/2 in. diameter by 11 ft. long.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Bingley Shell and Tube Heat Exchanger
Mfg: Bingley Steel Works Model:
Stock No. SNCC138.4 Serial: 195
Bingley Shell and Tube Heat Exchanger. S/N: 195. Tube material: 304 stainless steel. Number of passes: 1. Number of tubes: 100. Tube dimensions: 1 in. dia. x 8 ft. L. Heat transfer surface area: 209.4 sq. ft. Tube volume: 32.6 gallons. Design pressure: 75 psi @ 100°F. Shell thickness: 1/4 in. Head thickness: 3/16 in. Inlets: (2) 4 in. dia. ports, (1) 2 in. dia. port. Outlets: (2) 4 in. dia. ports, (1) 1-1/2 in. dia. port. Overall dimensions: 9 ft. 10 in. L x 2 ft. 10 in. W x 2 ft. 7 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Kinema Inc. Shell and Tube Heat Exchanger- 10 x 96
Mfg: Kinema Inc. Model:BEM
Stock No. SNCC151B. Serial: 36
Kinema Inc. Shell and Tube Heat Exchanger- 10 x 96. Model: BEM. S/N: 36. Heat transfer surface area: 113 sq. ft. Heat exchanged: 575,652/578,606 Btuh. (72) 3/4 in. dia. x 96 in. L tubes. Shell and tube construction: 304 stainless steel. Shell side fluid circulated: steam, CO2, air. Shell side total fluid entering: 714.5/840 pph. Shell side fluid entering (steam): 515/542 pph. Shell side fluid entering (non-condensables): 199.5/298 pph. Shell side entering temperature: 250 °F. Shell side leaving temperature: 125 °F. Shell side operating pressure: atmosphere. MAWP shell side 150 psi at 300 °F. Tube side circulated: water. Tube side flowrate: 80 gpm. Tube side entering temperature: 105/102 °F. Tube side leaving temperature: 120/116.6 °F. Tube side operating pressure: 35 psig. Number of passes: 4. Tube side MAWP: 75 psi at 150 °F. Inlets: (1) 2 in. dia. port, (1) 3 in. dia. media port. Outlets: (1) 1 in. dia. drain, (1) 1-1/2 in. media discharge, (1) 2 in. dia. port. Overall dimensions: 10 ft. 1 in. L x 30 in. W x 37-1/2 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Stainless Steel Shell and Tube Condenser
Mfg: Model:
Stock No. HDDF148C. Serial:
Stainless Steel Shell and Tube Condenser. Number of tubes: 32. Heat transfer surface area: approx. 100 sq. ft. Number of passes: 5. Overall dimensions: 14 ft. L x 48-1/2 in. W x 76 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Bell and Gossett SU-Series Shell and Tube Heat Exchanger
Mfg: Bell and Gossett Model:SU105-2
Stock No. JMB001a Serial:
Bell and Gossett SU-Series Shell & Tube Heat Exchanger. Model: SU105-2. Carbon steel shell. (76) ¾ in. dia. x 5 ft. L copper multi-tubes. Heat transfer surface area: ~ 71 sq. ft. Tube volume: 8.7 gal. The SU-series tube bundles are of “U”-bend construction. This allows ample expansion or contraction for wide temperature variations. Tube spacers properly support and space each tube for maximum efficiency in steam condensing and drainage. Inlets: (1) 6 in. dia. flanged port (media), (1) 4 in. dia. FNPT (product). Outlets: (1) 4 in. dia. FNPT (product), (1) 1 ½ in. dia. port (media). Overall dimensions: 5 ft. 4 in. L x 1 ft. 2 in. W x 1 ft. 6 in. H. (ACN50a)
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Croll Reynolds Co. Shell and Tube Heat Exchanger
Mfg: Croll Reynolds Co. Model:WP-304-L
Stock No. SNCC151C. Serial:
Croll Reynolds Co. Shell and Tube Heat Exchanger. Model: WP-304-L. (20) 1/2 in. dia. x 68 in. L stainless steel tubes. Inlets: (1) 1-1/2 in. dia. FNPT (product), (1) 2 in. dia. flanged port (media). Outlets: (1) 3/4 in. dia. port (pressure relief), (1) 1-1/2 in. dia. FNPT (product), (1) 2 in. dia. port (media). Overall dimensions: 88 in. L x 11 in. W x 18 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
2004 ITT Bell & Gossett Shell and Tube Heat Exchanger
Mfg: ITT Bell & Gossett Model:SU109-2
Stock No. DTTC2025. Serial: 938180-01
2004 ITT Bell & Gossett Shell and Tube Heat Exchanger. Model: SU109-2. S/N: 938180-01. Nat'l Bd: 123133. Front head material of construction: 316 stainless steel. (76) 5/8 in. dia. x 8 ft. 6 in. steel, multi-tubes. Heat transfer surface area: approx. 106 sq. ft. Volume: 10.4 gal. Shell side MAWP: 150 psi @ 375 °F. Shell side MDMT: -20 °F @ 150 psi. Tube side MAWP: 125 psi @ 375 °F. Tube side MDMT: -20 °F @ 125 psi. Inlets: (1) 4 in. dia. FNPT (product), (1) 6 in. dia. 150lb ANSI flanged port (media). Outlets: (1) 3/4 in. dia. FNPT (pressure relief), (1) 2 in. dia. FNPT (media), (1) 4 in. dia. FNPT (product). The “SU” Heat Exchanger instantaneous: designed to heat liquids with steam. No space-wasting, expensive storage tanks are needed. Although the “SU” is used for heating many types of fluids, its widest application is for heating water. The “SU” can also be used as a converter for use with radiation, radiant panels and snow melting systems. Overall dimensions: 11 ft. 2-1/2 in. L x 1 ft. 3 in. W x 1 ft. 6-1/2 in. H. (ACN68). FAD
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Patterson Kelley Co. Inc. Shell and Tube Heat Exchanger
Mfg: Patterson Kelley Co. Inc. Model:
Stock No. PMI07 Serial: 205007
Patterson Kelley Co. Inc. Shell and Tube Heat Exchanger. S/N: 205007 Std.Pa. – 31924. Tube material: carbon steel. Number of passes: 5. Number of tubes: 196. Tube dimensions: 5/8 in. dia. x 16 ft. L. Heat transfer surface area: approx. 513 sq. ft. Tube volume: 50 gal. Shell MAWP: 300 PSI @ 250 °F, Shell MDMT: 250 °F @ 300 PSI. Tube MAWP: 150 PSI @ 200 °F, Tube MDMT: 200 °F @ 150 PSI. Number of tubes: 196. Barrel dimensions: 16 in. dia. 10 ft. L. Approximate water required, 150 gpm with a 7 lb. approx pd. Capacity would be approx 2,900,000 to 3,000,000 btu/hr on ammonia. Water cooled oil cooler for Ammonia or Freon. Flanged inlets-outlets. Overall dimensions: 11 ft. 10 in. L x 45 in. W x 24 in. H. (ACN399).
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Blaw Knox Shell and Tube Heat Exchanger
Mfg: Blaw Knox Model:
Stock No. 85.H2002 Serial: 5230
Blaw Knox Shell and Tube Heat Exchanger. S/N: 5230. Stainless steel construction. Heat transfer surface area: approx. 25.3 sq. ft. Heat exchanger dimensions: 18-3/4 in. diameter x 10 ft. L. Tube lengths: 129-1/2 in. L. Inlets: (1) 1 in. dia. S-line fitting (product), (1) 3 in. dia. ANSI flange (steam). Outlets: (1) 1 in. dia. S-line fitting (product), (1) 1-1/2 in. dia. FNPT. Overall dimensions: 11 ft. L x 19 in. W x 53 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Chester Jensen Stainless Steel Shell and Tube Heat Exchanger
Mfg: Chester Jensen Model:SV-20
Stock No. 55.73 Serial: 5620-C
Chester Jensen Stainless Steel Shell and Tube Heat Exchanger. Model/Size: SV-20. S/N: 5620-C. Capacity: 18,000 lbs/hr (40 °F-90 °F), 20,000 lbs/hr (85 °F-190 °F), 20,000 lbs/hr (190 °F-230 °F). Tube material: 316 stainless steel. Number of passes: 4. Number of tubes: 24. Tube dimensions: 1-1/2 in. dia. x 10 ft. L. Heat transfer surface area: approx. 94.2 sq. ft. Tube volume: 20 gal. Steam heated and fully CIP-able. The Ste-Vac heater is specifically designed to heat milk and milk products without formation of milk stone or "burn-on" on the heating surfaces. Ste-vac heaters can be used in: powdered milk production as a pre-heater, pasteurizing cream as high-temperature-short-time pasteurizers, pre-heaters for fluid milk before entering vat pasteurizers, ice-cream mix processing, pre-heating milk for separators, and for pasteurizing milk in cheese production. Inlets: (1) 3-1/2 in. dia. FNPT fitting (media), (1) 1-1/2 in. dia. S-line infeed. Outlets: (1) 1-1/2 in. dia. FNPT fitting, (1) 1-1/2 in. dia. S-line drain port. Overall dimensions: 11 ft. 3 in. L x 2 ft. 6 in. W x 6 ft. 8 in. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Stainless Steel Shell and Tube Heat Exchanger
Mfg: Model:
Stock No. 172 Serial:
Stainless Steel Shell and Tube Heat Exchanger. Tube material: 316 stainless steel. Number of passes: 12. Number of tubes: 48. Tube dimensions: 1-1/2 in. dia. x 10 ft. 1-1/2 in. L. Heat transfer surface area: approx. 190.76 sq. ft. Tube volume: 44 gal. Inlets: (1) 1-1/2 in. dia. S-line fitting (product), (1) 1-1/2 in. dia. MPT (media). Outlets: (1) 1-1/2 in. dia. S-line fitting, (1) 1 in. dia. MPT (media). Overall dimensions: 11 ft. 4 in. L x 3 ft. 2 in.W x 8 ft. H.
Shell and Tube Heat Exchanger
Quote This Shell and Tube Heat Exchanger
Stainless Steel Shell and Tube Heat Exchanger
Mfg: Not Specified Model:
Stock No. OI239. Serial:
Stainless Steel Shell and Tube Heat Exchanger. Contact surface area: 268 sq. ft. Number of tubes: 54. Tube dimensions: 2 in dia. x 114 in. L. Carbon steel shell. Inlets: (1) 20 in. dia., 24-bolt flange, (1) 8 in. dia., 8-bolt