Inventory Index  >  Boilers  >  Firetube Boilers

Used Cleaver Brooks CB Packaged Steam Boiler-175 horse power. Model: CB-400-175S. Serial Number: L-67093. MAWP: 150 psi. Input: 7323000 btu per hour. Natural gas burner with standard 4:1 turndown. A firetube boiler is a cylindrical vessel, with the flame in the furnace and the combustion gases inside the tubes. The furnace and tubes are within a larger vessel containing the water which is converted to steam or hot water for process applications or hydronic comfort heating. Hot water is commonly used in heating applications with the boiler supplying water to the system at 180 °F to 220 °F. The operating pressure for hot water heating systems usually is 30 psig to 125 psig. Electrical requirements: 230 V, 43 amps, 60 Hz, 3 phase. Electrical control requirements: 120 V, 7 amps, 60 Hz, 3 phase. Boiler is equipped with a 48 inches length x 5 inches diameter Condenser tube. Entry into boiler is accessible through a 15 inches length x 11-1/2 inches width. Oval manway. Inlets: [1] 2-1/2 inches diameter pipe, [1] 3 inches diameter pipe for natural gas, [1] 4 inches diameter pipe, [1] 16 inches diameter with an 18-1/2 inches diameter flange and [12] 1/2 inches diameter attachment holes at a center-to-center distance of 18 inches Outlets: [1] 3/4 inches diameter pipe for condensate water, [1] 2 inches diameter pipe for blowdown water. Overall dimensions: 18 feet length x 6 feet width x 8 feet height.[h15](ACN952).
Stock No: fpe_pDFAO005.  |   Mfg: Cleaver Brooks  |   Model: CB-400-175S  |   S/N: fpe_L-67093

Used Cleaver Brooks CB Packaged Steam Boiler-175 horse power. Model: CB-400-175S. Serial Number: L-61662. MAWP: 150 psi. Input: 7,323,000 btu per hour. Natural gas burner with standard 4:1 turndown. A firetube boiler is a cylindrical vessel, with the flame in the furnace and the combustion gases inside the tubes. The furnace and tubes are within a larger vessel containing the water which is converted to steam or hot water for process applications or hydronic comfort heating. Hot water is commonly used in heating applications with the boiler supplying water to the system at 180 °F to 220 °F. The operating pressure for hot water heating systems usually is 30 psig to 125 psig. Electrical requirements: 230 V, 43 amps, 60 Hz, 3 phase. Electrical control requirements: 120 V, 7 amps, 60 Hz, 3 phase. Boiler is equipped with a 48 inches length x 5 inches diameter condenser tube. Entry into boiler is accessible through a 15 inches length x 11-1/2 inches width oval manway. Inlets: [1] 2-1/2 inches diameter pipe, [1] 3 inches diameter pipe for natural gas, [1] 4 inches diameter pipe, [1] 16 inches diameter with an 18-1/2 inches diameter flange and [12] 1/2 inches diameter attachment holes at a center-to-center distance of 18 inches Outlets: [1] 3/4 inches diameter pipe for condensate water, [1] 2 inches diameter pipe for blowdown water. Overall dimensions: 18 feet length x 6 feet width x 8 feet height.[h15](ACN952).
Stock No: fpe_pDFAO006.  |   Mfg: Cleaver Brooks  |   Model: CB-400-175S  |   S/N: fpe_L-61662

Used Cleaver Brooks CB Packaged Steam Boiler. Model: CB-400-175S. Rated horse power: 175. MAWP: 150 psi. Input: 7323000 Btu per hour. Natural gas burners with standard 4:1 turndown. A fire tube boiler is a cylindrical vessel, with the flame in the furnace and the combustion gases inside the tubes. The furnace and tubes are within a larger vessel containing the water which is converted to steam or hot water for process applications or hydronic comfort heating. Hot water is commonly used in heating applications with the boiler supplying water to the system at 180 °F to 220 °F. The operating pressure for hot water heating systems usually is 30 psig to 125 psig. Electrical requirements: 230 V, 43 amps, 60 Hz, 3 phase. Electrical control requirements: 120 V, 7 amps, 60 Hz, 3 phase. Condenser tube: 48 inches length x 5 inches diameter Oval manway: 15 inches length x 11-1/2 inches width. Inlets: [1] 2-1/2 inches diameter pipe, [1] 3 inches diameter pipe for natural gas, [1] 4 inches diameter pipe, [1] 16 inches diameter with an 18-1/2 inches diameter flange and [12] 1/2 inches diameter attachment holes center-to-center distance 18 inches Outlets: [1] 3/4 inches diameter pipe for condensate water, [1] 2 inches diameter pipe for blowdown water. Overall dimensions: 18 feet length x 6 feet width x 8 feet height. Sorgel single phase insulated transformer, 5 KVA, high voltage: 240/480, low voltage: 120/240. Spirax Sarco boiler water sampler, model: SC20, coil side MAWP: 100 bar g, body side MAWP: 10 bar g, coil side MDMT: 350 °C, body side MDMT: 100 °C, nominal volume coil side: 0.1 L, nominal volume body side: 1.4 L. Overall dimensions: 18 feet length x 6 feet width x 8 feet height.[h15](ACN952).
Stock No: fpe_pDFAO003.  |   Mfg: Cleaver Brooks  |   Model: CB-400-175S  |   S/N: fpe_L-61661