1991 Hurst Tubeless Vertical Boiler- 10 HP. Model: 4VT Cyclone. S/N: V49-150-25. Nat'l Bd: 1111. Steam output: 345 lbs/hr. Input required: 418,000 Btuh. Firing rate (natural gas): 215 cu. ft./hr. Water capacity @ nominal water level: 48 gal. Water capacity flooded: 68 gal. MAWP: 150 psi. Heating surface area: 49 sq. ft. Burner, Model S6, electrical requirements: 120V, 5.0 ams, 60 Hz, single phase. Blower Motor, 3/4 hp, 3450 rpm, 115/230 V, 12.4/6.2 amps, 60 Hz, 3 phase. The Hurst boiler's four-pass, high pressure design allows the gases that are leaving the furnace to be split though four individual serpentine fin passages to the stack outlet. Heat transfers evenly to the fins and boiler shell, eliminating the metal stress due to uneven heat transfer. Compact sized unit produces drier steam. Inlets: (1) 1/2 in. dia. NPT (male, gas), (1) 1 in. dia. bevel with hex nut (water). Outlets: (1) 3/4 in. dia. NPT (male, steam), (1) 8 in. dia. vent stack. Overall dimensions: 72 in. L x 52 in. W x 72 in. H.
Crown Hot Water Boiler. Model: AWI162SNSTIPSU, S/N: CROWNB000335746. Series: 2/3/2004. Input: 162,000 Btu/hr; Output: 132,000 Btu/hr. 4 hp. MAWP: 50 psi (water). Natural gas fired. Electrical requirements: 120 V, 60 Hz, < 12 amps. Max water temp: 250 F. Min relief valve capacity: 132 lb/hr, (1) 1 1/2 in. dia relief valve, (1) 1 1/2 in. dia gas valve. Overall dimensions: 29 in. L x 26 in. W x 40 in. H.
Crown Natural Gas Boiler. Model: AWI162SNSTIPSU, S/N: CROW32000320976, Series: 9/12/2003. Input: 162,000 Btu/hr; Output: 132,000 Btu/hr, 4 hp Max gas supply pressure: 14 (in w.c.), Min gas supply pressure: 5 (in w.c.), Manifold pressure: 3.5 (in w.c.), Electrical requirements: 120 V, 60 Hz, < 12 amps. Max water temp: 250 F. Min relief valve capacity: 132 lb/hr, (1) 1 1/2 in. dia relief valve, (1) 1 1/2 in. dia gas valve. Overall dimensions: 29 in. L x 26 in. W x 40 in. H.
Fulton Fuel-Fired Steam Boiler. Boiler No.: 66123, National Board No: 66123, Model: FB-006-A. Output: 201,000 Btu/hr. Hp: 6. Steam output: 207 lb/hr. MAWP: 15 psi. Max firing rate not to exceed 290,000 Btu/hr. Fuel outlet: 5-1/2 in. dia. Overall dimensions: 48 in. L x 36 in. W x 75 in. H.
SOLD York Shipley, Steam Pak Generator "boiler." The Model VTB16-1381. S/N 69-4619. 115Volt, 1 Phase. (1) Inlet 2 in. (1) outlets 1in. Burne mfr. Current is 3.6 amps, control current 4.0 amps. Firing rate 690cfh working pressure. Steam 125lbs neat surface 45.7. Type of cons. Welded. Boiler No. A89-305. Cap in BTU 536.000. Nat. Board No. 10.585. 552 lbs steam from 8 at 212 ? F. This unit was made 1969 and has been refurbished.
SOLD
Volcano gas fired boiler no. 214711C, natural gas, Model MF-1500C-W8 S/N 1207 contract no. C-52903, 150 hp, maximum allowable steam 200 psi at 388 degrees F (1379 kpa at 198 degrees C), power supply 440 volts 3 ph 60 hz, 27.1 heating surface power output 1,500 kw, input 1,876 kw, max rated steam capacity 5,291 lbs/hr (2,400 kg/hr), year.month 92/04 crn no. C-4875-6571 with a Baldor 5 hp 3,450 rpm motor and ITT General controls Hydramotor gas valve. Overall dimensions: 8 ft. H x 4 ft. W x 10 ft. L.
SOLD
Parker Boiler Co. 25 hp Steam Boiler. Model 103-25. Sales order 960001, natural gas fuel, max pressure 150 psi, maximum input rating 1,075,000 btu/hr, minimum input rating 537,500 btu/hr, 4 max. gas manifold pressure in. W.C., 7-14 in. W. C. Required fuel inlet supply pressure.
SOLD
SOLD 1999 Bryan 150 HP Water Tube Steam Boiler SOLD
Mfg: Bryan
Model:RV-05150S150FDG
Stock No. pHDHP140.50
Serial: 84918
1999 Bryan 150 HP Water Tube Steam Boiler. Model: RV-05150S150FDG. S/N: 84918. "Ohio Special" boiler with a maximum of 358 sq. ft. of heating surface. Capacity: 5,000 pph. Steam design pressure: 150 psig. Complete with Power Flame Burner flame retention head type burner for forced draft. Flame retention head type burner provides efficient combustion of oil or gas and ensures quiet operation, Model: CR4-G-30, S/N: 119991942, gas type: natural gas, opening time: 13 sec, max. closing time: 1 sec. Baldor Industrial Motor, 5 hp, 3450 rpm, 208-230/460 V, 13.2-12/6 amps, 60 Hz, 3 phase. Inlets: (1) 3-1/2 in. dia. inlet with a 14 in. dia. flange and (8) 3/4 in. dia. attachment holes,(1) 16 in. dia. inlet with 19-3/4 in. dia. flange and (16) 1/2 in. dia. attachment holes. Outlets: (1) 3/4 in. dia. FPT, (1) 1 in. dia. pipe, (2) 1 in. dia. MPT, (1) 1-1/2 in. dia. FPT, (1) 2 in. dia. threaded fitting. Overall dimensions: 13 ft. 8-1/2 in. L x 58 in. W x 9 ft. 5 in. H.
SOLD
SOLD York Shipley Steam-Pak Generator Boiler with Condensate Return Feed Water System- 44 HP
Mfg: York Shipley
Model:VTB300.30N168881
Stock No. 487
Serial: 86-16117H-91952
York Shipley Steam-Pak Generator Boiler with Condensate Return Feed Water System- 44 HP. Model: VTB300.30N168881. S/N: 86-16117H-91952. Nat'l Bd: 23486. Capacity: 1,500,000 Btuh. MAWP: 150 psi. Heating surface area: 62.6 sq.ft. Firing rate: 1250 cfh. Pounds of steam from and at 212 °F: 1,035 lbs. Motor and control electrical requirements: 120 V, 60 Hz, single phase. Packaged system, vertical tubeless boiler. Applications include: laundry, food preparation, hospitals, restaurants, light commercial and industrial, schools, institutional, multi-family dwellings. Inlets: (1) 1-1/4 in. dia. NPT (female, gas), (1) 1-1/4 in. dia. NPT (female, water). Outlets: (1) 1-1/4 in. dia. NPT (female, pressure relief), (1) 2 in. dia. NPT (female, steam). Overall dimensions: 64 in. L x 59 in. W x 9 ft. H.
SOLD