Stock No: fpe_ABCC201.55 |
Mfg: Trane |
Model: RTAA2154XN01A3COBK |
S/N: fpe_U97MO7068
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Stock No: fpe_CPEG601.50 |
Mfg: Trane |
Model: RTAA3004XM01A3D2ABFG |
S/N: fpe_U97D01336
|
|
|
|
|
|
|
|
|
|
|
|
|
Used 1996 Trane air cooled liquid chiller. Model: RTAA110AYF01A1COBK. Rated capacity: 110 tons. Refrigerant: R-22. Refrigerant side factory test pressure hi/lo: 450/300 psig. System requirements: 200 V, 60 Hz, 3 phase. [2] Trane Helirotor compressors. Compressor A: model: CHHN060AKB0N069A, charge: 98 pounds, electrical requirements: 200 V, 233 RLA, 1190 LRA, 60 Hz, 3 phase. Compressor B, Model: CHHN050AKB0N057A, charge: 73 pounds, electrical requirements: 200 V, 192 RLA, 990 LRA, 60 Hz, 3 phase. [10] Condenser Fan Motors, 1.5 horse power, 200 V, 5.1 FLA, 60 Hz, 3 phase. Control circuit requirements: 115 V, 750 VA max, 60 Hz, single phase. Evaporator heat tape, 115 V, 420 VA max, 60 Hz, single phase. Includes Trane adaptive control panel. Inlets/outlets: [2] 4 inches diameter ports. Overall dimensions: 19 feet 3 inches length x 7 feet 4 ½ inches width x 7 feet 2 inches H.[h15][ACN550].
|
|
Stock No: fpe_ADSP01 |
Mfg: Trane |
Model: RTAA110AYF01A1COBK |
S/N: fpe_U96B32701
|
|
|
|
|
|
|
|
|
|
|
|
|
Used 1991 Trane Air Cooled Liquid Chiller- 200 Ton. Model: RTAA2004XB01A1B0E. Serial Number: U91E04416. Refrigerant: R-22. Refrigerant side factory test pressure hi/lo: 450/300 psig. System requirements: 460 V, 60 Hz, 3 phase. Trane Helirotor Compressor, Model: CHHB100TNB0N119AN, Serial Number: UA1E4418, electrical requirements: 460 V, 163 RLA, 896 LRA, 60 Hz, 3 phase. [14] Condenser Fan Motors, 1 horse power, 460 V, 2.8 RLA, 60 Hz, 3 phase. Control circuit requirements: 115 V, 750 RLA, 60 Hz, single phase. Evaporator heat tape, 115 V, 480 RLA, 60 Hz, single phase. Inlets/outlets: [2] 6 inches diameter flanged ports. Overall dimensions: 23 feet length x 98 inches width x 93 inches height. [ACN741].
|
|
Stock No: fpe_SHCA128.44 |
Mfg: Trane |
Model: RTAA2004XB01A1B0E |
S/N: fpe_U91E04416
|
|
|
|
|
|
|
|
|
|
|
|
|
Used Giltron Water Recirculating Chiller. Model: WC-40, Serial Number: R-4144. Input Volts: 480. Tecumseh compressor, Model: AK100AT. Refrigerant: R-22. Capacity: 10,000 BTU per hour. Procon pump with Dayton motor: 1/4 horse power, 1725 rpm, 115 V, 5 amps, 60 Hz, 1 phase. Reservoir tank dimensions: 14 inches length x 10 inches width x 11 inches height. GE Fan motor: 1/20 horse power, 1550 rpm, 115 V, 2.5 amps, 60 Hz, 1 phase. Overall dimensions: 33 inches length x 15 inches width x 40 inches height.
|
|
Stock No: fpe_9a.FHF166.1a |
Mfg: Giltron |
Model: WC-40 |
S/N: fpe_R-4144
|
|
|
|
|
|
|
|
|
|
|
|
|
Used Giltron Water Recirculating Chiller. Model: WC-40, Serial Number: R-4138. Tecumseh compressor, Model: AK100AT. Refrigerant: R-22. Capacity: 10,000 BTU per hour. Procon pump with Dayton motor: 1/4 horse power, 1725 rpm, 115 V, 5 amps, 60 Hz, 1 phase. Reservoir tank dimensions: 14 inches length x 10 inches width x 11 inches height. GE Fan motor: 1/20 horse power, 1550 rpm, 115 V, 2.5 amps, 60 Hz, 1 phase. Overall dimensions: 33 inches length x 15 inches width x 40 inches height.
|
|
Stock No: fpe_9a.FHF167.1a |
Mfg: Giltron |
Model: WC-40 |
S/N: fpe_R-4138
|
|
|
|
|
|
|
|
|
|
|
|
|
Used Giltron Water Recirculating Chiller. Model: WC-40, Serial Number: R-4134. Tecumseh compressor, Model: AK100AT. Refrigerant: R-22. Capacity: 10,000 BTU per hour. Procon pump with Dayton motor: 1/4 horse power, 1725 rpm, 115 V, 5 amps, 60 Hz, 1 phase. Reservoir tank dimensions: 14 inches length x 10 inches width x 11 inches height. GE Fan motor: 1/20 horse power, 1550 rpm, 115 V, 2.5 amps, 60 Hz, 1 phase. Overall dimensions: 33 inches length x 15 inches width x 40 inches height.
|
|
Stock No: fpe_9a.FHF168.1a |
Mfg: Giltron |
Model: WC-40 |
S/N: fpe_R-4134
|
|
|
|
|
|
|
|
|
|
|
|
|
Used 1990 Snyder General / McQuay Air cooled Chiller 125 Tons. Model ALRC125C. Serial Number 5VJ0178900. Refrigerated System. [4] 35 horse power Compressors, 56 RLA, 283 LRA [EA], 460 V, 60 Hz, 3 phase, [12] Cond. Fan Motor. 1 horse power, 2.0/5.6 Fla, 9.9/14.5 LRA, 230/460 V, 60 Hz, 1 phase, [4] Crankcase HTRS. 0.87 A, 115 V, 60 Hz, 1 phase. [1] Evaporator HTRS. 3.2 A, 115 V, 60 Hz, 1 phase, single Power Supply, All Loads, 267 amps [min.], 300 amps [max.], 460 V, 60 Hz, 3 phase R-22 refrigerant, 141 lb. charge. Inlet: [1] 8 bolt 6 inches diameter flange. Outlet: [1] 6 inches diameter bolt. Overall dimensions: 18 feet 8 inches length x 91 inches width x 92 inches height. [ACN400]
|
|
Stock No: fpe_cDPLS228.23 |
Mfg: Snyder General |
Model: ALRC125C |
S/N: fpe_5VJ0178900
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Stock No: fpe_WCNT76.42 |
Mfg: McQuay |
Model: ALR195C-X |
S/N: fpe_55J8131001
|
|
|
|
|
|
|
|
|
|
|
|
|
Used 1999 Carrier Air Cooled Chiller. Model: 30GT100 610KA. Rated nominal cooling capacity: 100 tons. Refrigerant: R-22. Respective high and low design/test pressures: 450/278 psi. [4] Carlyle compressors. Model: 06EF275310: 208/230-460V, 60 Hz, 3 phase, or 400V, 50 Hz, 3 phase. [8] fans, 6 blades, 30 inches diameter, 1.0 hp, 460V, 60 Hz, 3 phase. Overall dimensions: 15 feet 2 inches L x 8 feet 2 inches W x 8 feet 2 inches H.
|
|
Stock No: fpe_ABCC202.50 |
Mfg: Carrier |
Model: 30GT100 610KA |
S/N: fpe_2999F35349
|
|
|
|
|
|
|
|
|
|
|
|
|
Used 1994 Dunham-Bush Air Cooled Chiller-225 Tons. Model ACDX225B. Serial Number 2864401A94F. Pressure Test: 400 PSI high side, 250 PSI low side. Unit: 460 V, 60 Hz, 3 phase. CNT: 115 V, 60 Hz, 1 phase. [4] Compressor Motors, Model: SSCA075AR, 103 RLA, 180 LRA, 460 V, 60 Hz, 3 phase. [4] Condenser Fan Motors, 1 horse power, 460 V, 2.4 amps, 60 Hz, 3 phase. [16] Condenser Fan Motors, 1-1/2 horse power, 460 V, 2.0 amps, 60 Hz, 3 phase. [4] Crankcase Heaters, 200 horse power, 115 V, 1.7 amps, 60 Hz, 1 phase. [3] Chiller Heater, 420 horse power, 115 V, 3.7 amps, 60 Hz, 1 phase. Cond. Of Service – 599 gallons per minute/43 pgR-22 refrigerant with 484 lb. charge. Inlet: [1] 6 inches dia port. Outlet: [1] 8 bolt 6 inches dia flange. Overall dimensions: 37 feet 4 inches length x 100 inches width x 92-1/2 inches height. [ACN1035].
|
|
Stock No: fpe_DPLS230.43a |
Mfg: Dunham-Bush |
Model: ACDX225B |
S/N: fpe_2864401A94F
|
|
|
|
|
|
|
|
|
|
|
|
|
Used 1997 Carrier Air Cooled Chiller. Model: 30GT100 610KA. Rated nominal cooling capacity: 100 tons. Refrigerant: R-22. Respective high and low design/test pressures: 450/278 psi. [3] Carlyle compressors. Model: 06EF275310: 208/230-460V, 60 Hz, 3 phase, or 400V, 50 Hz, 3 phase. [1] Carlyle compressor. Model: 06E6265310: 230/460V, 60 Hz, 3 phase. [8] fans, 6 blades, 30 inches diameter, 1.0 hp, 460V, 60 Hz, 3 phase. Overall dimensions: 15 feet 2 inches L x 8 feet 2 inches W x 8 feet 2 inches H.
|
|
Stock No: fpe_ABCC203.50 |
Mfg: Carrier |
Model: 30GT100 610KA |
S/N: fpe_1897F70945
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Stock No: fpe_GAMP021.250 |
Mfg: Carrier |
Model: 30XAB2606M-OGSD3 |
S/N: fpe_1710Q91422
|
|
|
|
|
|
|
|
|
|